Read Harman Kardon HD 980 (serv.man5) EMC - CB Certificate online
Page 12 of 51 Report No. SH08050531-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
TR1 basic insulation minimum
5.0 mm between TR1 core
and primary, Supplementary
insulation minimum 5.0mm
between TR1 core and
secondary.
5.0 mm between TR1 core
and primary, Supplementary
insulation minimum 5.0mm
between TR1 core and
secondary.
Pass
Coil formers and partition walls > 0,4 mm
TR1 bobbin: 0.8mm min.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II construction
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
TR1 basic insulation minimum
5.0 mm between TR1 core
and primary, Supplementary
insulation minimum 5.0mm
between TR1 core and
secondary.
5.0 mm between TR1 core
and primary, Supplementary
insulation minimum 5.0mm
between TR1 core and
secondary.
Pass
Coil formers and partition walls > 0,4 mm
TR1 bobbin: 0.8mm min.
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II construction
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No such components
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
Pass
Protective devices used within their ratings
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Fuse FU1: 4.9mm
Pass
14.5.1.1
a) Thermal cut-outs separately approved
No such components
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
Click on the first or last page to see other HD 980 (serv.man5) service manuals if exist.