                                                                                Page 13 of 51                        Report No. SH08050531-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.5.1.2 
a) Thermal links separately approved 
No such components 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
FU1 approved. 
Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : FU1: T1A L 250V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : Only one fuse holder 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
Tools required. 
 
N/A 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No such parts 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
 
N/A 
14.6 Switches 
No 
switch 
N/A 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
         
 N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
         
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
         
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
         
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
         
 N/A 