Read Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate online
<12007721 001>
Page 30 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
Temperature T
1
=T
2
= T
mra
– T
amb
+10K (
°
C)......... :
N
2.10.8
Spacings filled by insulating compound................ : Certified opto-coupler used.
No other components applied
for. (see appended table
2.10.5).
P
Electric strength test
Ditto.
2.10.9
Component external terminations
See appended table 2.10.3
and 2.10.4.
P
2.10.10
Insulation with varying dimensions
Insulation kept homogenous.
N
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1
General
P
3.1.1
Current rating and overcurrent protection
Secondary output cable is UL
recognized wiring which is
PVC insulated, rated VW-1,
min. 80°C, 30V.
No internal wire for primary
No internal wire for primary
power distribution.
P
3.1.2
Protection against mechanical damage
Wires do not touch sharp
edges and heatsinks which
could damage the insulation
and cause hazard.
P
3.1.3
Securing of internal wiring
Internal wires are secured by
solder pins or glued so that a
loosening of the terminal
connection is unlikely.
P
3.1.4
Insulation of conductors
The insulation of the individual
conductors are suitable for the
application and the working
voltage. For the insulation
material see 3.1.1.
P
3.1.5
Beads and ceramic insulators
Not used.
N
3.1.6
Screws for electrical contact pressure
No such screws provided.
N
3.1.7
Non-metallic materials in electrical connections
All current carrying and safety
connections are metal to
metal.
N
3.1.8
Self-tapping and spaced thread screws
No self tapping screws are
used.
N
3.1.9
Termination of conductors
All conductors are reliable
secured.
P
10 N pull test
Compliance.
P