GO AND PLAY (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 123

Read Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate online

 
 
<12007721 001> 
 
 
Page 26 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
 
Measured capacitance (
µ
F)..................................:  3300pF 
 
2.4.3 
Connection of limited current circuits to other 
circuits 
Output circuit as limited 
current circuit connected to 
primary via one bridging 
capacitor. 
 
2.5 
Limited power sources 
 
Inherently limited output 
 
 
Impedance limited output 
 
 
Overcurrent protective device limited output 
 
 
Regulating network limited output under normal 
operating and single fault condition 
 
 
Regulating network limited output under normal 
operating conditions and overcurrent protective 
device limited output under single fault condition 
See appended table 2.5. 
 
Output voltage (V), output current (A), apparent 
power (VA)............................................................: 
Complies. 
 
 
Current rating of overcurrent protective device (A)  See pages 12 to 19.  
 
 
2.6 
Provisions for earthing and bonding 
2.6.1 
Protective earthing 
Class II equipment. 
2.6.2 
Functional earthing 
Secondary functional ground 
separated to primary by 
reinforced or double insulation. 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
2.6.3.1 
Size of protective earthing conductors 
No power cord provided. 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG .....................................................................: 
 
 
2.6.3.2 
Size of protective bonding conductors 
 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG .....................................................................: 
 
 
2.6.3.3 
Rated current (A), type and nominal thread 
diameter (mm) ......................................................: 
 
 
Resistance (
) of earthing conductors and their 
terminations, test current (A) ................................: 
 
2.6.3.4 
Colour of insulation ...............................................:   
2.6.4 
Terminals 
 
Page of 127
Display