Read Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate online
<12007721 001>
Page 22 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
1.5.7.2
Bridging resistors
No bridging resistors.
N
1.5.7.3
Accessible parts
See 2.4.
P
1.5.8
Components in equipment for IT power systems
Class II equipment.
N
1.6
Power interface
P
1.6.1
AC power distribution systems
TN power system. IT power
system for Norway.
P
1.6.2
Input current
Highest load according to
1.2.2.1 for this equipment is
the operation with the max.
specified DC-load.
Results see appended table
Results see appended table
P
1.6.3
Voltage limit of hand-held equipment
This appliance is not a hand-
held equipment.
N
1.6.4
Neutral conductor
Class II equipment. Phase
conductors separated to body
by reinforced insulation.
N
1.7
Marking and instructions
P
1.7.1
Power rating
See below.
P
Rated voltage(s) or voltage range(s) (V) .............: AC 100-240V~
P
Symbol for nature of supply for d.c. .....................: Mains from AC source
N
Rated frequency or frequency range (Hz) ............: 47-63Hz
P
Rated current (A) .................................................: 2A MAX.
P
Manufacturer’s name/Trademark ........................: SPEC LIN
P
Type/model ..........................................................: S60-XXXYYY-WZ, S60-
XXXYYY-WZL
(XXX= 090-320, YYY=125-
(XXX= 090-320, YYY=125-
500, Z = H01-H99)
P
Symbol of Class II ................................................: Double square symbol
provided.
P
Other symbols ......................................................: Additional symbols or marking
does not give rise to
misunderstanding.
P
Certification marks ...............................................: See the copy of marking
plate.
N
1.7.2
Safety instructions
User’s manual provided.
P
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
N