IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
1
GENERAL
P
1.5
Components
P
1.5.1
Comply with IEC 60950 or relevant component
standard
Components which were
found to affect safety aspects
comply with the requirements
of this standard or within the
safety aspects of the relevant
IEC component standards.
(see appended table 1.5.1)
P
1.5.2
Evaluation and testing of components
Components which are
certified to IEC and /or
national standards are used
correctly within their ratings.
Components not covered by
IEC standards are tested
under the conditions present
in the equipment.
P
Dimensions (mm) of mains plug for direct plug-in : Not direct plug in type.
N
Torque and pull test of mains plug for direct
plug-in; torque (Nm); pull (N) ................................:
N
1.5.3
Thermal controls
N
1.5.4
Transformers
Transformer used is suitable
for its intended application and
comply with the relevant
requirements of the standard
and particularly Annex C.
P
1.5.5
Interconnecting cables
Interconnection o/p cable to
other device is carrying only
SELV on an energy level
below 240VA.
→
Except the insulation
material, there are no further
requirements to the o/p
interconnection cable.
P
1.5.6
Capacitors in primary circuits ............................... : Between lines: X2 capacitor
according to IEC 60384-
14:1993 with 21 days damp
heat test.
P
1.5.7
Double or reinforced insulation bridged by
components
See below.
P
1.5.7.1
Bridging capacitors
Primary and secondary
bridged by one capacitor
(CY2), which used was
certified as Y1 capacitor
according to IEC 60384-
14/1993.
P
Click on the first or last page to see other GO AND PLAY (serv.man4) service manuals if exist.