Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
Pass
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
T502: pin3- 14, 250Vrms,
600Vp
600Vp
Pass
13.3 Clearances
Primary—secondary: 4.6mm
required
required
Primary (operating voltage:
240Vrms) —accessible parts
/ enclosure: 4.0mm required
240Vrms) —accessible parts
/ enclosure: 4.0mm required
Primary (operating voltage:
250Vrms, 600Vp) —
accessible parts / enclosure:
4.6mm required
250Vrms, 600Vp) —
accessible parts / enclosure:
4.6mm required
L-N before fuse link:
2.0mm required
T502: P—S: 4.6mm required
Pass
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9
with table 8 and, where applicable, table 9
Measured distance:
Primary—secondary:
>5.4mm
>5.4mm
Primary—accessible parts /
enclosure (operating voltage:
240Vrms): >4.7mm
enclosure (operating voltage:
240Vrms): >4.7mm
Primary—accessible parts /
enclosure (operating voltage:
250Vrms, 600Vp): >5.4mm
enclosure (operating voltage:
250Vrms, 600Vp): >5.4mm
T502: P—S: >5.4mm
L-N before fuse link: >4.0mm
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N/A