Read Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate online
page 6 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Pass
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Pass
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
R574,T502 Pass
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
CY2, CY3, CY501, CY502
Pass
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No such voltage
N/A
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V (peak)
a.c. or between 60 V and 120 V d.c. and hazardous
live parts at higher voltage
operating at voltages between 35 V and 71 V (peak)
a.c. or between 60 V and 120 V d.c. and hazardous
live parts at higher voltage
N/A
Separation by Class II isolating transformer
N/A
Separation by Class I transformer
N/A
Separation by earthed conductive part
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) .................... : T502 bobbin: 0.9mm
Optocoupler U502: 0.40mm
Enclosure (front panel):
>1.5mm
>1.5mm
Separation sheet on internal
enclosure under power
board: 0.5mm.
enclosure under power
board: 0.5mm.
Pass
Thin sheet insulation
Inside T502
Pass
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Click on the first or last page to see other DVD 23 (serv.man11) service manuals if exist.