DVD 23 (serv.man11) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 10

Read Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate online

 
 
page 8 of  63 
Ref. No. : JSH05110330-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
Pass 
9.1 
Testing on the outside 
Pass 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No such high voltage 
N/A 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. : 
U1<0.86Vp  
U2<0.113Vp 
Pass 
 
Discharge not exceeding 45 μC <1μC Pass 
 
Energy of discharge not exceeding 350 mJ 
No voltage exceeding 15kV 
N/A 
9.1.1.2 
Test with test finger and test probe 
 Pass 
9.1.2 
No hazardous live shafts of knobs, handles or levers  Pass 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin 
< 2 mm, no entering 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032 
 Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set control 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  : 
< 5V 
Pass 
 
If C is not greater than 0,1 μF no test needed 
> 0.2 μF 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
 Pass 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 Pass 
 
Test hook of fig. 4 for 10 s (20 N) 
 
Pass 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... :  100N Pass 
9.2 
No hazard after removing a cover by hand 
Can not be removed by hand 
N/A 
 
 
 
10 INSULATION 
REQUIREMENTS 
Pass 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. : 
No antenna terminal. 
N/A 
10.2 Humidity 
treatment 48 h or 120 h ........................... :  120h, 40℃, 93%R.H. 
Pass 
10.3 
Insulation resistance and dielectric strength 
(See appended table) 
Pass 
 
 
 
 
11 FAULT 
CONDITIONS 
Pass 
11.1 
No shock hazard under fault condition 
           
Pass 
Page of 65
Display

Click on the first or last page to see other DVD 23 (serv.man11) service manuals if exist.