Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
Pass
9.1
Testing on the outside
Pass
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No such high voltage
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U1<0.86Vp
U2<0.113Vp
U2<0.113Vp
Pass
Discharge not exceeding 45 μC <1μC Pass
Energy of discharge not exceeding 350 mJ
No voltage exceeding 15kV
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or levers Pass
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
< 2 mm, no entering
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set control
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
< 5V
Pass
If C is not greater than 0,1 μF no test needed
> 0.2 μF
N/A
9.1.7
Enclosure sufficiently resistant to external force
Pass
Test probe 11 of IEC 61032 for 10 s (50 N)
Pass
Test hook of fig. 4 for 10 s (20 N)
Pass
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N Pass
9.2
No hazard after removing a cover by hand
Can not be removed by hand
N/A
10 INSULATION
REQUIREMENTS
Pass
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
No antenna terminal.
N/A
10.2 Humidity
treatment 48 h or 120 h ........................... : 120h, 40℃, 93%R.H.
Pass
10.3
Insulation resistance and dielectric strength
(See appended table)
Pass
11 FAULT
CONDITIONS
Pass
11.1
No shock hazard under fault condition
Pass