DVD 23 (serv.man11) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 15

Read Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate online

 
 
page 13 of  63 
Ref. No. : JSH05110330-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T502 basic insulation 
minimum 3.0 mm between 
T502 core and primary, 
Supplementary insulation 
minimum 3.0mm between 
T502 core and secondary. 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T502 bobbin: 0.9mm 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II construction 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Iron cores in T502 are not 
connected to primary parts or 
accessible parts. 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T502 bobbin: 0.9mm 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Class II construction 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
No such components 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved 
 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 Protective 
devices 
 
Pass 
 
Protective devices used within their ratings 
 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Fuse F501: >3.5mm 
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such components 
N/A 
 
b) Thermal cut-outs tested as part of the submission   
N/A 
14.5.1.2 
a) Thermal links separately approved 
No such components 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
Page of 65
Display