DPR 1005 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 14

Read Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 10 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
HEATING  
 
∆t =  ( R2 - R1)    x (234,5 + t1) - (t2 - t1) 
               R1 
t1 =   
23,0 °C 
23,0 °C
 
 
t2 =   
23,4 °C 
23,9 °C
 
 
Test voltage  
207 V 
253 V
 
 
Winding 
R1/
Ω R2/Ω 
∆t measured
∆t allowed *) 
Insulation 
class 
T101 winding at 207 V 
679 
833 
58,0 
85 
Class E 
T101 winding at 253 V 
679 
876 
73,8 
85 
Class E 
 
 
 
 
 
 
Other measured parts 
∆t measured
at 207V 
∆t measured 
at 253V 
∆t allowed *) 
Linear transformer, T101 core 
47,8 
56,5 
85 
Switching transformer, T102 core 
25,8 
27,8 
70 
Switching transformer, T102 coil 
28,5 
30,4 
70
 
Switching transformer, T103 core 
27,3 
29,2 
70
 
Switching transformer, T103 coil 
28,8 
31,0 
70 
Switching transformer, T201 core 
26,6 
28,1 
70 
Switching transformer, T201 coil 
27,3 
28,8 
70
 
Switching transformer, T202 core 
28,2 
30,4 
70
 
Switching transformer, T202 coil 
28,4 
30,7 
70 
Line chock, T203 coil 
28,2 
30,7 
70 
Reactor, PT01 coil 
17,8 
17,2 
70 
Line filter, LF101 coil 
15,1 
15,9 
70 
Line filter, LF102 coil 
14,8 
15,7 
70 
PFC, L206 coil 
21,5 
23,2 
70 
Diode, BD101 body 
25,9 
27,3 
PWB near BD101 
24,8 
26,5 
85 
PWB near D215 
34,5 
39,4 
85 
HS104 heat-sink 
26,7 
28,6 
E. Capacitor, C107 body 
22,7 
25,0 
85°C 
PWB near Q105 
26,8 
30,0 
85 
PWB near U101 
27,3 
30,7 
85 
Page of 53
Display