Read Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 9 of 41 -
Order
No.
26088
7.1
Operating conditions:
Sine wave 1000Hz input, set to 1/8 of maximum output power for Front,
Center, Surr. and Surr.Back channels.
Center, Surr. and Surr.Back channels.
U
=
207,0
V, I
=
1,12
A, P
=
136
W,
Pout =
2 x 8,70
W
(F)
1 x 9,19
W
(C)
2 x 8,70
W
(S)
2 x 8,78
W
(S/B)
U
=
253,0
V, I
=
0,96
A, P
=
142
W,
Pout =
2 x 8,70
W
(F)
1 x 9,19
W
(C)
2 x 8,70
W
(S)
2 x 8,78
W
(S/B)
LSL
= 8
Ω x 7 channels ( Front: 2, Center: 1, Surround: 2, Surround Back: 2 )
Loudspeaker system(s)
Right and Left for Front,
One for Center,
Right and Left for Surround Back,
Right and Left for Surround channels.
Marking of loudspeaker terminals
SPEAKERS 8
Ω :
CENTER, FRONT L / R,
SURR. L / R, SBL / MULTI L / R.
U =
253,0
V
4 Ohm
8 Ohm
16 Ohm
6
Ohm
Left Right
Left
Right
Left Right
Left Right
Measured output voltage in Vp
F) 33,4
C) 34,3
S) 33,4
S/B) 33,5
C) 34,3
S) 33,4
S/B) 33,5
F) 33,4
C) -
S) 33,4
S/B) 33,5
C) -
S) 33,4
S/B) 33,5
Measured output power in W
F) 69,6
C) 73,5
S) 69,6
S/B) 70,2
C) 73,5
S) 69,6
S/B) 70,2
F) 69,6
C) -
S) 69,6
S/B) 70,2
C) -
S) 69,6
S/B) 70,2
Measured mains power in W
660
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible
parts
parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as
a support or as a mechanical
barrier
a support or as a mechanical
barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)
P