DPR 1005 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 9

Read Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 5 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
Standardized approval marks  
 
  
1  
SCOPE 
According to standards mentioned. 
9 
2  
DEFINITIONS  
According to standards mentioned. 
9 
3  
GENERAL REQUIREMENTS  
According to standards mentioned. 
9 
 
Safety class of the apparatus 
Class II 
9 
4  
GENERAL CONDITIONS FOR 
TESTS  
According to standards mentioned. 
9 
4.1.4 - 
4.2.12. 
Normal operating 
conditions/position/adjustments 
With all users controls set to obtain maximum power 
from the mains and at 1/8 of max. audio output power. 
Positioned according to users manual. 
9 
MARKING AND INSTRUCTIONS 
 
 
Copy of the markings :
 
 
 
 
 
 
Comprehensible and easily 
discernible  
On front and rear side of the enclosure 
 
Permanent durability against water 
and petroleum spirit  
Tested with water / spirit 
5.1 
Identification, maker, model    
 
 
Class II symbol  
Provided double square marking on the rear enclosure 
 
Rated supply voltage and symbol   
AC-symbol ( 
~
 ), 230V marked 
 
Rated mains frequency 
 
50Hz 
 
Rated current or power 
consumption    
650 W 
Page of 53
Display

Click on the first or last page to see other DPR 1005 (serv.man13) service manuals if exist.