Read Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 13 of 41 -
Order
No.
26088
8.7
Basic insulation between parts at
35 V to 71 V (peak) a.c. or 60 V to
120 V d.c. and accessible parts
35 V to 71 V (peak) a.c. or 60 V to
120 V d.c. and accessible parts
No parts at 35-71V a.c. or 60-120V d.c.
N
Reinforced or double insulation
between circuits operating at
voltages between 35 V and 71 V
(peak) a.c. or between 60 V and
120 V d.c. and hazardous live parts
at higher voltage
between circuits operating at
voltages between 35 V and 71 V
(peak) a.c. or between 60 V and
120 V d.c. and hazardous live parts
at higher voltage
No parts at 35-71V a.c. or 60-120V d.c.
N
Separation by Class II isolating
transformer
transformer
Isolating transformer according to 14.3.2. (Class II)
P
Separation by Class I transformer
N
Separation by earthed conductive
part
part
N
8.8
Basic or supplementary insulation
≥ 0,4 mm (mm)
≥ 0,4 mm (mm)
Insulation in reactor PT01 (before mains fuse),
partition walls
partition walls
≥ 0,4 mm between W1 and W2 windings,
meet 10.3.
P
Reinforced insulation
≥ 0,4 mm
(mm)
Insulation in transformers and reactor, ref. 14.3.
P
Thin sheet insulation used inside
the enclosure
the enclosure
P
Basic or supplementary insulation,
at least two layers, each meeting
10.3
at least two layers, each meeting
10.3
N
Basic or supplementary insulation,
three layers any two of which meet
10.3
three layers any two of which meet
10.3
N
Reinforced insulation, two layers
each of which meet 10.3
each of which meet 10.3
N
Reinforced insulation, three layers
any two which meet 10.3
any two which meet 10.3
T102, T103, T201, T202 Transformers with thin sheet
insulation, ref. 14.3.
insulation, ref. 14.3.
P
8.9
Primary wiring :
Adequate insulation between
internal hazardous live conductors
and accessible parts
Adequate insulation between
internal hazardous live conductors
and accessible parts
Double insulated
P
Secondary wiring :
Adequate insulation between
internal hazardous live parts and
conductors connected to accessible
parts
Adequate insulation between
internal hazardous live parts and
conductors connected to accessible
parts
Single insulated but safely anchored
P
8.10
Class II apparatus :
Double insulation between
conductors connected to the mains
and accessible parts
Double insulation between
conductors connected to the mains
and accessible parts
Double insulated, tested according to 8.9. and 10.3.
P
Click on the first or last page to see other DPR 1005 (serv.man13) service manuals if exist.