DPR 1005 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 15

Read Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 11 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
HEATING (continued) 
Other measured parts (continued) 
∆t measured
at 207V 
∆t measured 
at 253V 
∆t allowed *) 
HS102 heat-sink 
28,7 
32,9 
Top enclosure above Amp. Module 
13,1 
12,7 
40 
Top enclosure above SMPS 
15,3 
17,1 
40 
Amp. Module body 
26,6 
25,7 
Appliance inlet body 
13,7 
13,2 
60 
Switch button (standby / on) 
1,4 
1,5 
50 
 
 
 
 
 
 
 
 
Comments  
 
 
No other parts were observed to create any hazard due to temperature rise.  
P 
 
*) Temperature rise limits for Singapore is 10K less. 
 
 
 
 
 
 
 
 
7.2 
Softening temperature of insulating 
material supporting parts 
conductively connected to the mains 
carrying a current > 0,2 A at least 
150 
°C  
No temperatures measured during heating test and fault 
cond. tests requires this test (7.2) to be performed. 
Tested parts 
Temperature 
under normal 
operating con- 
ditions (°C) 
Temperature 
under fault 
conditions  
     (°C) 
Softening 
Temperature 
       (°C) 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 53
Display