DMC 1000 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 100

Read Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate online

 
 
 
 
Page 96 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  ............. :  Rated voltage: 100-240 V
 
Test voltage: 264 V 
 
— 
 
Ambient temperature (
o
C)  ...................................... :  23.7 
 25.5 
— 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C)  .................................. :  23.7 
 25.5 
— 
 
Ambient temperature t2 (
o
C)  .................................. :  23.7 
 25.5 
— 
No. 
component 
No. 
fault 
test 
voltage 
(Vac) 
test time 
fuse 
No. 
fuse 
current 
(A) 
result 
Ventilation 
opening 
264 
1.5 hours 
F1 
0.329 
Transformer coil temp. rise: T1 coil 
= 47.9K; T2 coil = 37.4K  
Clause 9: Pass 
Hi-pot: Pass 
Operated until steady state. No 
damage. No hazards. 
DC fan (All) 
264 
2 hours 
F1 
0.329 
Transformer coil temp. rise: T1 coil 
= 56.1K; T2 coil = 40.1K  
Clause 9: Pass 
Hi-pot: Pass 
Operated until steady state. No 
damage. No hazards. 
supplementary information 
Note: 
1)  S: Short-circuited; O: Open-circuited; O/L: Overloaded; B: Blocked; L: Locked. 
2)  The fuse number “F1” is part of the certified building-in power supply module. 
 
Page of 116