Read Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate online
Page 96 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. : Rated voltage: 100-240 V
Test voltage: 264 V
—
Ambient temperature (
o
C) ...................................... : 23.7
−
25.5
—
Winding temperature rise measurements
Ambient temperature t1 (
o
C) .................................. : 23.7
−
25.5
—
Ambient temperature t2 (
o
C) .................................. : 23.7
−
25.5
—
No.
component
No.
fault
test
voltage
(Vac)
test time
fuse
No.
fuse
current
(A)
result
1
Ventilation
opening
B
264
1.5 hours
F1
0.329
Transformer coil temp. rise: T1 coil
= 47.9K; T2 coil = 37.4K
Clause 9: Pass
Hi-pot: Pass
Operated until steady state. No
damage. No hazards.
= 47.9K; T2 coil = 37.4K
Clause 9: Pass
Hi-pot: Pass
Operated until steady state. No
damage. No hazards.
2
DC fan (All)
L
264
2 hours
F1
0.329
Transformer coil temp. rise: T1 coil
= 56.1K; T2 coil = 40.1K
Clause 9: Pass
Hi-pot: Pass
Operated until steady state. No
damage. No hazards.
= 56.1K; T2 coil = 40.1K
Clause 9: Pass
Hi-pot: Pass
Operated until steady state. No
damage. No hazards.
supplementary information
Note:
1) S: Short-circuited; O: Open-circuited; O/L: Overloaded; B: Blocked; L: Locked.
2) The fuse number “F1” is part of the certified building-in power supply module.
Click on the first or last page to see other DMC 1000 (serv.man2) service manuals if exist.