Read Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate online
Page 94 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
7.1
TABLE: temperature rise measurements (cont.)
P
Monitored point:
dT (K)
Limit dT (K)
L1 coil (front panel)
8.3
18.0
45 (105-50-10)
T1 coil (front panel)
8.8
18.4
45 (105-50-10)
Metal enclosure outside
3.8
8.8
25 (40-15)
Front panel outside
10.7
13.5
45 (60-15)
Power switch body
6.8
5.1
35 (50-15)
Winding temperature rise measurements
Ambient temperature t1 (
o
C) .................................. :
24.1
25.4
—
Ambient temperature t2 (
o
C) .................................. :
25.4
25.1
—
Temperature rise dT of winding:
R
1
(
Ω
)
R
2
(
Ω
)
dT (K)
Limit dT
(K)
Insulation
class
—
—
—
—
—
—
Note:
Maximum room ambient temperature:
The apparatus was submitted and evaluated for maximum manufacturer’s recommended ambient (Tmra) of
50
50
°
C. The apparatus is considered as may be used in tropical conditions.
7.2
TABLE: softening temperature of thermoplastics
P
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
Primary connector (housing) (type TU6002)
—
—
155