Page 92 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
5.1
TABLE: electrical data (in normal conditions)
P
fuse #
Irated (A) /
Prated (W)
U (V)
P (W)
I (A)
Ifuse (A)
condition/status
F1
—
90 V / 50 Hz
63.0
0.707
0.707
Maximum normal load
F1
—
90 V / 60 Hz
63.0
0.709
0.709
Maximum normal load
F1
135 W
100 V / 50 Hz
63.2
0.641
0.641
Maximum normal load
F1
135 W
100 V / 60 Hz
63.2
0.642
0.642
Maximum normal load
F1
—
108 V / 50 Hz
63.2
0.594
0.594
Maximum normal load
F1
—
108 V / 60 Hz
63.2
0.596
0.596
Maximum normal load
F1
—
120 V / 50 Hz
62.7
0.532
0.532
Maximum normal load
F1
—
120 V / 60 Hz
62.8
0.534
0.534
Maximum normal load
F1
—
125 V / 50 Hz
62.3
0.510
0.510
Maximum normal load
F1
—
125 V / 60 Hz
62.2
0.510
0.510
Maximum normal load
F1
—
216 V / 50 Hz
62.2
0.350
0.350
Maximum normal load
F1
—
216 V / 60 Hz
62.2
0.360
0.360
Maximum normal load
F1
135 W
240 V / 50 Hz
62.7
0.337
0.337
Maximum normal load
F1
135 W
240 V / 60 Hz
62.7
0.347
0.347
Maximum normal load
F1
—
250 V / 50 Hz
62.8
0.332
0.332
Maximum normal load
F1
—
250 V / 60 Hz
62.9
0.347
0.347
Maximum normal load
F1
—
254.4 V / 50 Hz
62.8
0.331
0.331
Maximum normal load
F1
—
254.4 V / 60 Hz
62.9
0.347
0.347
Maximum normal load
F1
—
264 V / 50 Hz
59.5
0.311
0.311
Maximum normal load
F1
—
264 V / 60 Hz
59.5
0.329
0.329
Maximum normal load
Note:
1) The measured input current or power consumption at rated voltage shall be
≤
110 % of rated current or
power consumption.
2) The fuse number “F1” is part of the certified building-in power supply module.