Read Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate online
Page 97 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
13.3 and
13.4
13.4
TABLE: clearance and creepage distance measurements
P
clearance cl and creepage
distance dcr at/of:
distance dcr at/of:
Up
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required
dcr (mm)
dcr
(mm)
On PCB solder side:
Line and Neutral before fuse-
link (F1) (BI)
link (F1) (BI)
340
240
2.0
3.7
2.5
3.7
Line/Neutral and earth (metal
enclosure) (BI)
enclosure) (BI)
340
240
2.0
3.3
2.5
3.3
On PCB component side:
Line and Neutral before fuse-
link (F1) (appliance inlet) (BI)
link (F1) (appliance inlet) (BI)
340
240
2.0
10.0
2.5
10.0
Line and Neutral before fuse-
link (F1) (on PCB) (BI)
link (F1) (on PCB) (BI)
340
240
2.0
6.5
2.5
6.5
Line/Neutral and earth (metal
enclosure) (BI)
enclosure) (BI)
340
240
2.0
3.5
2.5
3.5
Note:
1) BI: Basic insulation; SI: Supplementary insulation; DI: Double insulation; RI: Reinforced insulation.
2) A force of 2 N is applied to the internal components and 30 N is applied to the enclosure when
measuring the distances.
Click on the first or last page to see other DMC 1000 (serv.man2) service manuals if exist.