ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
13.3 and 
13.4 
TABLE: clearance and creepage distance measurements 
clearance cl and creepage 
distance dcr at/of: 
Up 
(V) 
U r.m.s. 
 (V) 
required cl 
 (mm) 
cl 
 (mm) 
required 
 dcr (mm) 
dcr 
(mm) 
On PCB solder side: 
Line and Neutral before fuse- 
link (F1) (BI) 
340 
240 
2.0 
3.7 
2.5 
3.7 
Line/Neutral and earth (metal 
enclosure) (BI) 
340 
240 
2.0 
3.3 
2.5 
3.3 
On PCB component side: 
Line and Neutral before fuse- 
link (F1) (appliance inlet) (BI) 
340 
240 
2.0 
10.0 
2.5  
10.0 
Line and Neutral before fuse- 
link (F1) (on PCB) (BI) 
340 
240 
2.0 
6.5 
2.5  
6.5 
Line/Neutral and earth (metal 
enclosure) (BI) 
340 
240 
2.0 
3.5 
2.5 
3.5 
Note: 
1)  BI: Basic insulation; SI: Supplementary insulation; DI: Double insulation; RI: Reinforced insulation. 
2)  A force of 2 N is applied to the internal components and 30 N is applied to the enclosure when 
measuring the distances. 
Page of 116