Read Sony DCR-HC1000 / DCR-HC1000E (serv.man5) Service Manual online
Sony EMCS Co.
2004G1600-1
©2004.7
Published by DI Technical Support Section
9-876-752-81
SERVICE MANUAL
Ver 1.1 2004.07
SUPPLEMENT-1
File this supplement-1 with the service manual.
(PV04-008)
• Addition of Adjustment data
• Correction of Adjustment data
• Correction of Adjustment data
ADJ
DCR-HC1000/HC1000E
RMT-831
Before change
After change
Page 6-27
: Added portion
: Changed portion
9. MAX GAIN Adjustment
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
96
Set the following data.
29 (NTSC), 17 (PAL)
29 (NTSC), 17 (PAL)
3
6
97
00
Set the data.
4
6
01
6F
Set the data, and press PAUSE
button.
button.
5
6
02
Check that the data changes to
“01”. (Note5)
“01”. (Note5)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
23
Set the data.
3
E
53
DD
Set the data.
4
Check that the white balance is
stabilized.
stabilized.
5
6
01
00
Set the data.
6
6
96
Set the following data.
2A (NTSC), 14 (PAL)
2A (NTSC), 14 (PAL)
7
6
97
00
Set the data.
8
6
01
6F
Set the data, and press PAUSE
button.
button.
9
6
02
Check that the data changes to
“01”. (Note5)
“01”. (Note5)
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
96
00
Set the data.
2
6
97
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
button.
4
0
01
00
Set the data.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
96
00
Set the data.
2
6
97
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
button.
4
E
53
DC
Set the data.
5
0
01
00
Set the data.
— 2 —
DCR-HC1000/HC1000E
Before change
After change
Page 6-28
: Changed portion
: Deleted portion
: Added portion
10. F No. & ND Light Quantity Standard Data Input
PAL
99
8F
87
83
90
89
89
88
Address
1C
1D
1E
1F
20
21
22
23
NTSC
99
8F
87
83
90
89
89
88
Data
PAL
80
80
80
80
80
80
80
80
Address
1C
1D
1E
1F
20
21
22
23
NTSC
80
80
80
80
80
80
80
80
Data
Page 6-29
12. Auto White Balance Adjustment
Adjusting method:
Order Page Address Data
Procedure
3
F
3C
2B
Set the data, and press PAUSE
button.
button.
4
F
3D
F4
Set the data, and press PAUSE
button.
button.
Adjusting method:
Order Page Address Data
Procedure
3
F
3C
Set the following data, and
press PAUSE button.
2B (NTSC), 2C (PAL)
press PAUSE button.
2B (NTSC), 2C (PAL)
4
F
3D
Set the following data, and
press PAUSE button.
F4 (NTSC), 34 (PAL)
press PAUSE button.
F4 (NTSC), 34 (PAL)
Note6: NTSC model : DCR-HC1000
PAL model
: DCR-HC1000E
Page
Added contents
6-23
Preparation of Flange Back Adj.
(Using the flange back adjustment jig)
(Luminance: about 300 lux)
1)
(Using the flange back adjustment jig)
(Luminance: about 300 lux)
1)
Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
tween it and the front of lens of camera is less than 3 cm.
2)
Make the height of flange back adjustment jig and the camera
equal.
equal.
3)
Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Flange back adjustment jig
Below 3 cm
Camera
Fig. 6-1-10.
Display