ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
(see appended table 11.2) 
11.2.5 
Temperature rise of windings 
(see appended table 11.2) 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table 11.2) 
 
12 
MECHANICAL STRENGTH 
 
12.1.1 
Bump test where mass > 7 kg 
Approx. 8.6 kg, the EUT is still 
complying with relevant 
requirements of this standard 
12.1.2 
Vibration test 
The EUT is still complying with 
relevant requirements of this 
standard 
12.1.3 
Impact hammer test 
The EUT is still complying with 
relevant requirements of this 
standard 
 
Steel ball test 
The EUT is still complying with 
relevant requirements of this 
standard 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
Approx. 8.6 kg 
N/A 
12.1.5 
Thermoplastic enclosures stress relief test 
70 
°
C / 7 hours, all the 
enclosure materials listed in 
the table 14 are tested. After 
the test, no dangerous moving 
parts or hazardous live parts 
are accessible 
12.2 
Fixing of knobs, push buttons, keys and levers 
The EUT is still complying with 
relevant requirements of this 
standard 
12.3 
Remote controls with hazardous live parts 
No remote control device with 
hazardous live parts 
12.4 
Drawers (pull test 50 N, 10 s) 
The EUT is still complying with 
relevant requirements of this 
standard 
12.5 
Antenna coaxial sockets providing isolation 
No antenna coaxial socket is 
provided 
N/A 
12.6 
Telescoping or rod antennas construction 
No such device  
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
Page of 116