Read Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate online
Page 11 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
Measured open-circuit voltage
between mains and user
accessible parts: max. 388
Vpeak;
U1: max. 0.54 Vpeak;
U2: max. 0.31 Vpeak;
between mains and user
accessible parts: max. 388
Vpeak;
U1: max. 0.54 Vpeak;
U2: max. 0.31 Vpeak;
Touch current measured max.
0.38 mA (limit: 3.5 mA, Class I
construction)
0.38 mA (limit: 3.5 mA, Class I
construction)
P
Discharge not exceeding 45
µ
C
< 45
µ
C
P
Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
No hazardous live parts are
accessible by the test finger
accessible by the test finger
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
No hazardous live shafts of
operating knobs, handles,
levers or the likes are used
operating knobs, handles,
levers or the likes are used
N/A
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
The test pin was not became
hazardous live
hazardous live
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
The test probe was not
became hazardous live
became hazardous live
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
The test probe was not
became hazardous live
became hazardous live
P
9.1.5
Pre-set controls tested with 2,5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set control
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
Measured max. 4 Vpeak after
2 s
2 s
P
If C is not greater than 0,1
µ
F no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
After the tests as below, the
EUT shown no damage and
hazardous live parts are not
accessible
EUT shown no damage and
hazardous live parts are not
accessible
P
Test probe 11 of IEC 61032 for 10 s (50 N)
P
Test hook of fig. 4 for 10 s (20 N)
P
30 mm diameter test tool for 5 s (100 or 250 N) ... : 100 N
P
9.2
No hazard after removing a cover by hand
No such cover provided
N/A
Click on the first or last page to see other DMC 1000 (serv.man2) service manuals if exist.