DMC 1000 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 15

Read Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate online

 
 
 
 
Page 11 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 
N/A 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. : 
Measured open-circuit voltage 
between mains and user 
accessible parts: max. 388 
Vpeak;                                  
U1: max. 0.54 Vpeak;            
U2: max. 0.31 Vpeak;       
Touch current measured max. 
0.38 mA (limit: 3.5 mA, Class I 
construction) 
 
Discharge not exceeding 45 
µ
< 45 
µ
 
Energy of discharge not exceeding 350 mJ 
 
N/A 
9.1.1.2 
Test with test finger and test probe 
No hazardous live parts are 
accessible by the test finger  
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
No hazardous live shafts of 
operating knobs, handles, 
levers or the likes are used 
N/A 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
The test pin was not became 
hazardous live 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
The test probe was not 
became hazardous live 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
The test probe was not 
became hazardous live 
9.1.5 
Pre-set controls tested with 2,5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set control 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  : 
Measured max. 4 Vpeak after 
2 s  
 
If C is not greater than 0,1 
µ
F no test needed 
 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
After the tests as below, the 
EUT shown no damage and 
hazardous live parts are not 
accessible  
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
 
Test hook of fig. 4 for 10 s (20 N) 
 
 
30 mm diameter test tool for 5 s (100 or 250 N)  ... :  100 N 
9.2 
No hazard after removing a cover by hand 
No such cover provided 
N/A 
Page of 116
Display