DMC 1000 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate online

 
 
 
 
Page 9 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Evaluated in approved 
building-in power supply 
module 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
No such capacitor 
N/A 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
No such capacitor 
N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
Evaluated in approved 
building-in power supply 
module 
8.7 
This clause is void 
 
N/A 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) 
................................................................................. : 
Primary lead wire: min. 0.4 
mm; 
Evaluated in approved 
building-in power supply 
module 
 
Reinforced insulation > 0,4 mm (mm)  ................... :  Evaluated in approved 
building-in power supply 
module 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) 
Evaluated in approved 
building-in power supply 
module 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 
N/A 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 
 
N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 
N/A 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
All internal wires with only 
basic insulation are routed so 
that they are not close to any 
live bare components 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
All internal hazardous live parts 
are separate by double or 
reinforced insulation from 
these conductors 
Page of 116