Page 9 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
No such capacitor
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
No such capacitor
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
8.7
This clause is void
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm)
................................................................................. :
Primary lead wire: min. 0.4
mm;
mm;
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
Reinforced insulation > 0,4 mm (mm) ................... : Evaluated in approved
building-in power supply
module
module
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
All internal wires with only
basic insulation are routed so
that they are not close to any
live bare components
basic insulation are routed so
that they are not close to any
live bare components
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
All internal hazardous live parts
are separate by double or
reinforced insulation from
these conductors
are separate by double or
reinforced insulation from
these conductors
P