Read Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate online
Page 10 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
8.10
Double insulation between conductors connected
to the mains and accessible parts.
Double insulation between internal hazardous live
parts and conductors connected to accessible
parts
to the mains and accessible parts.
Double insulation between internal hazardous live
parts and conductors connected to accessible
parts
The EUT is Class I apparatus
N/A
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
All wires are fixed by double
securement
securement
P
Vibration test carried out ........................................ : See sub-clause 12.1.2
P
8.12
This clause is void
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
No such device
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
No such cover
N/A
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
The internal lead wires are
secured away from the hot
parts and sharp edges by the
construction
secured away from the hot
parts and sharp edges by the
construction
P
8.16
Only special supply equipment can be used
The EUT is supplied from AC
mains
mains
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
No such insulated winding wire
N/A
8.18
Endurance test as required by 8.17
See above
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
The mains plug is used as the
disconnect device and see
also sub-clause 5.4.2
disconnect device and see
also sub-clause 5.4.2
P
All-pole switch or circuit breaker with > 3 mm
contact separation
contact separation
See sub-clause 8.19.1
N/A
8.19.2
Mains switch ON indication
See sub-clause 8.19.1
N/A
8.20
Switch not fitted in the mains cord
No mains switch is fitted in the
mains cord
mains cord
P
8.21
Bridging components comply with clause 14
No such component within the
EUT
EUT
N/A
8.22
Non-separable thin sheet material
No such material
N/A
Click on the first or last page to see other DMC 1000 (serv.man2) service manuals if exist.