Read Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate online
Page 8 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Evaluated in approved
building-in power supply
module and see also
appended table 7.2
building-in power supply
module and see also
appended table 7.2
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Windings are covered by
lacquer
lacquer
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No such components are
replaced by hand
replaced by hand
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
The EUT is complied with the
requirements
requirements
P
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
Also evaluated in approved
building-in power supply
module
building-in power supply
module
P
A resistor bridging basic insulation complying with
14.1 a)
14.1 a)
No such resistor
N/A
A capacitor bridging basic insulation complying
with 14.2.1 a)
with 14.2.1 a)
Evaluated in approved
building-in power supply
module
building-in power supply
module
P
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Evaluated in approved
building-in power supply
module
building-in power supply
module
P