DMC 1000 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate online

 
 
 
 
Page 8 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts 
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
(see appended table 7.1) 
7.1.4 
Temperature rise of windings 
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
Evaluated in approved 
building-in power supply 
module and see also 
appended table 7.2 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Windings are covered by 
lacquer 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
No such components are 
replaced by hand 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic material used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
The EUT is complied with the 
requirements 
8.5 
Class I equipment 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
Also evaluated in approved 
building-in power supply 
module 
 
A resistor bridging basic insulation complying with 
14.1 a) 
No such resistor 
N/A 
 
A capacitor bridging basic insulation complying 
with 14.2.1 a) 
Evaluated in approved 
building-in power supply 
module 
8.6 
Class II equipment and Class II constructions within Class I equipment 
 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
Evaluated in approved 
building-in power supply 
module 
Page of 116
Display