Read Harman Kardon BDS 275 EMC - CB Certificate online
Page 10 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U1: 19000mV, U2: 267mV
Limit: U1:35000mV,
U2:350mV
U2:350mV
P
c) Discharge not exceeding 45
μC
P
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
Can’t touch hazardous parts
P
9.1.2
No hazardous live shafts of knobs, handles or levers No such parts
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set control
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
13.5V after 2s
P
If C is not greater than 0,1
μF no test needed
N/A
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
50N
P
b) Test hook of fig. 4 for 10 s (20 N)
20N
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
100N
P
9.2
No hazard after removing a cover by hand
Cover cannot be removed by
hand
hand
N/A
10
Insulation requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4
surge test for basic and 4
MΩ min. for reinforced
insulation ................................................................. :
(see appended table)
P
10.2
Humidity treatment 48 h or 120 h ........................... :
120 hour, 40
C, 93%
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
P
11
Fault conditions
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
P