BDS 275 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon BDS 275 EMC - CB Certificate online

 
Page 10 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. : 
U1: 19000mV, U2: 267mV 
Limit: U1:35000mV, 
U2:350mV 
 
c) Discharge not exceeding 45 
μC  
 
 
d) Energy of discharge not exceeding 350 mJ 
 
N/A 
9.1.1.2 
Test with test finger and test probe  
Can’t touch hazardous parts 
9.1.2 
No hazardous live shafts of knobs, handles or levers   No such parts 
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set control 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
13.5V after 2s 
 
If C is not greater than 0,1 
μF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
50N 
 
b) Test hook of fig. 4 for 10 s (20 N)  
20N 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
100N 
9.2 
No hazard after removing a cover by hand  
Cover cannot be removed by 
hand 
N/A 
 
10 
Insulation requirements 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 
MΩ min. for reinforced 
insulation  ................................................................. : 
(see appended table) 
10.2 
Humidity treatment 48 h or 120 h  ........................... : 
120 hour, 40
C, 93% 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
 
 
11 
Fault conditions 
 
11.1 
No shock hazard under fault condition  
 
11.2 
Heating under fault condition  
 
 
Flames extinguish within 10 seconds  
 
Page of 127