BDS 275 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 10

Read Harman Kardon BDS 275 EMC - CB Certificate online

 
Page 8 of 40 
 
 
Report Ref. No.: 211-2012016-000 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Limited. - Shenzhen Branch 
 
TRF No. IEC60065K 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
  
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
No hygroscopic material used 
N/A 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
 
8.5 
Class I equipment  
Class II equipment 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
Class II equipment  
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
Isolating transformer T501 and 
T502 used  
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)   
Approved Y1-cap. (CY501, 
CY502, CY504, CY506) used 
8.7 
This clause is void  
 
— 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
T501 Bobbin: min. 1.0mm 
 
Reinforced insulation > 0,4 mm (mm)  .................... : 
T502 Bobbin: min. 0.9mm 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
Insulation tape wrapped in 
T501. 
 
Page of 127