IEC 60065, 6th edition : 1998
 - 
- Page 23 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
14.6.6.b. 
Manually operated mechanical 
switch (MOMS) tested as part of the 
equipment complies with 14.6.7, 
14.6.10 and 20.1.4 and meets 14.6.8 
and/or 14.6.9 and Annex G (G1.1)   
 
 
Flame test for mains switches   
 
14.6.7 Endurance 
test 
 
14.6.8 
Temperature rise in mains switch 
 
14.6.9 
Dielectric strength test 
 
14.6.10 
Surge current for mains switches 
also controlling mains socket-outlets
Measured surge current for, 
- Mains switch  : < 1A peak. 
- Mains relay 
: < 37A peak + 20A peak* for 50W 
 
Rated surge current for, 
- Mains switch: 80A 
 
 
: OK 
- Mains relay, SK11: 120A. 
 
: OK 
 
*) Calculated surge current for switched socket outlet. 
14.7 Safety 
interlocks 
 
 
 
Safety interlocks to 2.8 of 
IEC 60 950   
No safety interlock 
 
14.8 
Voltage setting devices 
 
 
 
Voltage setting device not likely to be 
changed accidentally   
No voltage selector 
 
14.9 Motors 
 
 
14.9.1 
Endurance test on motors   
Only DC low voltage secondary connected motors for fan, 
no further testing required. 
 
Motor start test   
 
 
Dielectric strength test   
 
14.9.2 
Not adversely affected by oil or 
grease etc.   
 
14.9.3 
Protection against moving parts   
No moving parts 
14.9.4 
Motors with phase-shifting 
capacitors, three-phase motors and 
series motors meet Cl. B.8, B.9 and 
B.10 of IEC 60 950, Annex B   
 
14.10 Batteries 
 
 
14.10.1 
Batteries mounted with no risk of 
accumulation of flammable gases   
No batteries 
 
14.10.2 
No possibility of recharging non-
rechargeable batteries   
 
Page of 49