AVR 4550 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 21

Read Harman Kardon AVR 4550 EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 19 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
14.3.3-5 Transformer 
construction 
See below. 
14.3.3.2 
Transformers meet the 
constructional requirements : 
See below. 
Transformer/motor Insulation Insulation 
Test  Flashover 
Creepage 
distances 
Part No/markings 
between 
resistance 
voltage 
Breakdown 
and clearances 
 
 
  M Ohm 
kV(60)s 
voltage kV 
Measured 
Required  
55589450NR 
Pr - sec 
> 100 
3KV(rms) 
> 7,0 mm 
≥≥≥≥
 6 mm 
 
Pr - ic 
> 100 
3KV(rms) 
> 7,2 mm 
≥≥≥≥
 6 mm 
 
 
 
 
 
 
 
55643480NR 
Pr - sec 
> 100 
3KV(rms) 
> 6,6 mm 
≥≥≥≥
 6 mm 
 
Pr - ic 
> 100 
3KV(rms) 
> 6,2 mm 
≥≥≥≥
 6 mm 
 
 
 
 
 
 
 
 
Components / construction 
(Main transformer)
   
Windings on two separate bobbins. The bobbins are 
placed in an insulating housing with two compartments, 
one above the other. Bobbin thickness: > 0,4mm. 
 
Components / construction 
(Sub transformer)
   
Windings on single bobbins. A wall (2 layers) is provided 
between primary and secondary windings. Satisfactory 
constructed. Bobbin thickness: > 0,4mm. 
Transformer/mot
or 
Insulation 
Thickness (mm) 
Material 
Dielectric strength test 
Part 
No/markings 
between 
      X 
 
for each combination of 
 
 
    Number 
 
two (2) layers  
55589450NR 
Pr - sec 
0,80 mm min. x 1 
PBT bobbin 
Pass *) 
 
Pr - ic 
0,80 mm min. x 1 
PBT bobbin 
Pass *) 
 
 
 
 
 
55643480NR 
Pr - sec 
0,50 mm min. x 2 
PETP bobbin wall 
Pass    *) 
 
Pr - ic 
0,60 mm min. x 1 
66 Nylon bobbin cap. 
Pass    *) 
 
Pr - ic 
0,70 mm min. x 1 
PETP bobbin 
Pass    *) 
 
 
 
 
 
*) Test voltage: 3000 Vrms. 
14.3.4.1 
Class II transformers have adequate 
separation between hazardous live 
windings and windings intended to 
be connected to accessible 
conductive parts (double or 
reinforced insulation)   
Double or reinforced insulation between primary and 
secondary windings according to clause 8.8. 
 
 
Coil formers and partition walls 
 0,4 mm   
The bobbin(s) fulfils the requirement of reinforced 
insulation, see table above for bobbin thickness. 
Page of 49