AVR 4550 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 24

Read Harman Kardon AVR 4550 EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 22 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
14.6 Switches 
 
 
 
Manually operated mechanical 
switch (MOMS) conductively 
connected to the mains
 
 
 
Part No 
Function 
Manufacturer 
Type 
Rated 
Marking 
 
All- 
One 
Name 
Trademark 
 
V A Surge 
 
pole 
pole 
 
 
 
  current
 
 
 
 
 
 
 
 
 
 
Alps Electric Co., Ltd. 
SDL1P-D 
250 
80A 
SK11 
 x 
Original 
Electromecha. 
OEG 
SDT-S-112DMR 250 
8 120A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14.6.1 
Permanently connected equipment 
provided with an all-pole mains 
switch unless 5.4.2 is met   
Apparatus is not permanently connected 
 
14.6.2 
Manually operated mechanical 
switch (MOMS), required where 
power consumption > 15 W and/or 
peak voltage > 4 kV 
Yes. MOMS required. See table above. 
 
 
Switch readily accessible and not in 
mains cord   
Switch located on the front and readily accessible 
 
 
Exception for automatic switching   
 
 
Exception for continuous operation   
 
14.6.3 
Manually operated mechanical 
switch (MOMS): Switch indication / 
On position clearly discernible   
The display is illuminated. 
 
 
Indication by marking meets Cl. 5   
Yes 
 
 
Indication of the OFF position   
Off-position marked with “OFF” 
14.6.4 
Manually operated mechanical 
switch (MOMS) fitted. Is there a 
Stand-by mode      
Yes 
 
 
Stand-by mode clearly discernible    
LED indication 
 
Exception for low Stand-by current 
< 0,7 mA (peak)   
 
14.6.5 
Components bridging contacts of 
mains switches comply with 14.1 a) 
or 14.2.2   
Yes. See clause 14.2.2. 
 
14.6.6.a. 
Manually operated mechanical 
switches (MOMS) separately 
approved to IEC 61 058-1   
Yes.  
- Mains switch, certified by VDE, 
- Mains relay, certified by SEMKO. 
Page of 49
Display