AVR 4550 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 26

Read Harman Kardon AVR 4550 EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 24 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
14.10.3 
Recharging currents and times 
within manufacturers limits   
 
 
Lithium batteries discharge and 
reverse currents within the 
manufacturers limits   
 
14.11 Optocouplers 
 
 
 
Optocouplers comply with Cl. 8   
No optocouplers. 
 
Internal and external dimensions to 
13.1.1  
 
 
15 TERMINALS 
 
 
15.1.1 
Mains plug, appliance inlet, 
interconnection couplers and mains 
socket-outlet meet the appropriate 
standard  
See list below. 
Component Manufacturer 
Type  Standard 
Certified 
Remarks 
  
 
sheet 
by 
(colour 
etc.) 
Appliance inlet 
I-SHENG 
7014 
IEC 60320 
VDE 
Black, 10A 250V 
Mains  
socket- outlet 
Dae Ryung Electronic 
A3-04-D007 
IEC 60884-1 
NEMKO 
Black, 2.5A 250V~ 
 
 
 
 
 
 
 
 
 
 
 
 
 
Mains sockets and interconnection 
couplers 
The socket outlet on the Class II apparatus does only 
permit connection of other Class II apparatus. 
 
Overload protection for   
socket-outlets 
Overload protection provided with a fuse: 
F102, T3.15A L 250V 
15.1.2 
Connectors for antenna, earth, 
audio, video or data: 
 
 
 
No risk of insertion in mains 
socket-outlets  
Only phono/RCA, Optical, Mini jack, Antenna, S-video, 
A-BUS and RS-232 terminal used. Banana plug type 
speaker terminal also used, but they are accepted due to 
below note. 
 
Note:  
Banana plug type speaker terminals are blocked in their 
axial holes to prevent use of plugs that can make 
permanent contact with a mains socket outlet. 
 
Sockets for audio and video circuits 
indicated with the symbol of 5.2.b. 
No sockets indicated with the symbol   
15.1.3 
Output terminals of AC adaptors or 
similar devices not compatible with 
household mains socket-outlets   
 
Page of 49
Display