Read Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate online
-
Page
8
of
31
-
www.nemko.com
Report No.
72390
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No parts at 35-71V(peak) a.c.
or 60-120V d.c.
or 60-120V d.c.
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
No parts at 35-71V(peak) a.c.
or 60-120V d.c.
or 60-120V d.c.
N
Separation by Class II isolating transformer
Isolating transformer
according to 14.3.2. (Class II)
according to 14.3.2. (Class II)
P
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N
Reinforced
insulation > 0,4 mm (mm) .................... :
Transformer bobbin,
See appended table and
attachment, Table to
EN/IEC 60065 7
See appended table and
attachment, Table to
EN/IEC 60065 7
th
edition
P
Thin sheet insulation
No thin sheet insulation
N
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated.
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Single insulation but safely
anchored
anchored
P
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Double insulated, tested
according to 8.9. and 10.3.
according to 8.9. and 10.3.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires connected with
multi-contact-housing.
multi-contact-housing.
P
Vibration
test carried out ........................................ :
See 12,1,2
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
No internal wiring for socket-
outlets, but protective fuse
provided (F201, T2A L 250V)
outlets, but protective fuse
provided (F201, T2A L 250V)
P
TRF No: IEC/EN 60065F