AVR 445 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 9

Read Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate online

  
Page 
7
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
(see appended table) 
7.1.4 
Temperature rise of windings 
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
Approved components 
according to relevant IEC 
stanards.. 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Considered
 
P
 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Operation “By hand” 
not possible 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic materials used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No cover removable by hand 
8.5 
Class I equipment 
Class II equipment 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
 
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
Class II apparatus. 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
Double/Reinforced insulation 
complies with requirements 
specified in clause 10 and 13. 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
The apparatus have isolating 
transformers. 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
No such capacitors. 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
No such capacitors.
 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
No such capacitors.
 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
No such components.
 
TRF No:  IEC/EN 60065F 
Page of 46
Display