AVR 445 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 8

Read Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate online

  
Page 
6
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
5.4 
Instructions for use 
User information in the 
following language: English. 
See comments in Summary of 
testing. 
5.4.1 
Mains powered equipment not exposed to dripping 
or splashing. Warning concerning objects filled 
with liquid, etc. 
The user manual includes 
information about danger 
concerning dripping or 
splashing and objects filled 
with liquids. 
 
Hazardous live terminals, instructions for wiring 
No hazardous live terminals. 
 
Instructions for replacing lithium battery 
No lithium battery in the 
equipment 
 
Instructions for modem if fitted 
None 
 
Class I earth connection warning 
Class II apparatus 
 
Instructions for multimedia system connection 
Not applicable 
 
Special stability warning for fixed installation 
No such equipment 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
Appliance coupler is 
disconnecting device. 
Adequate information included 
in “User manual” 
 
Instructions for permanently connected equipment
Not permanently connected 
equipment 
 
 
 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No Ionizing radiation. 
6.1 
EN 60065 
European Council Directive 96/29/Euratom of 13 
May 1996 10cm from outer surface of apparatus 
<1µSv/h (0,1mR/h) 
 
6.2 
Laser radiation, emission limits to IEC 60825-1  .... :
No laser radiation. 
 
Emission limits under fault conditions .................... :
 
 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
No fuse links operate during 
normal operating operation. 
(see appended table) 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table) 
TRF No:  IEC/EN 60065F 
Page of 46
Display