AVR 445 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 39

Read Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate online

 
 
- Page 6 of 8 - 
 
 
   
 Order 
No. 
72390
 
 
 
11 
FAULT CONDITON TESTS -continued 
Comp. 
No. 
Location 
Fault   Test V 
Test 
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
Speaker 
terminal 
(Front) 
R - G 
S-c 253 
10 min 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
Cover 
opening 
Blocked 
253 
Top 
5 hr 
F101 
2,73 A 
Normal operated. 
The components are heated up to: 
- Main transf. pr. winding : 80K 
- Main transformer core : 68K 
- Sub transf. pr. winding : 51K 
- Sub transformer core  : 52K 
- PWB near D201 
: 41K 
- PWB near Q334 
: 37K 
and stabilised. 
Dielectric strength test OK. 
No hazard. 
Fan Locked 
253 
min. 
30 sec. 
F101 
2,73 A 
Unit shut down after 4min. 30sec.
Input current stabilised at 0,06A. 
No component damaged. 
and stabilised. 
Dielectric strength test OK. 
No hazard. 
Pmax 
operat. 
Maximum 
non-
clipped 
output 
signal 
253 
7 min. 
F101 
5,70 A 
The components are heated up to:
- Main transf. pr. winding  : 143K 
- Main transformer core  : 90K 
- Sub transf. pr. winding  : 60K 
- Sub transformer core 
: 58K 
- PWB near D201 
: 74K 
- PWB near Q334 
: 38K 
and main transformer thermal 
fuse opened after 7 min. 
Dielectric strength test OK. 
No hazard. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded 
TRF No:  IEC/EN 60065F 