FAULT CONDITON TESTS –continued
P
Comp.
No.
No.
Location
Fault Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
C202 -
S-c 253
10
min. F101
10,7 A
F101 opened after 32sec.
Input current stabilised at 0,06A.
Main transformer damaged.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,06A.
Main transformer damaged.
Dielectric strength test OK.
No hazard.
C202 -
S-c 207
10
min. F101
10,3 A
F101 opened after 1min. 4sec.
Input current stabilised at 0,03A.
Main transformer damaged.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,03A.
Main transformer damaged.
Dielectric strength test OK.
No hazard.
D105
A - C
S-c 253
2
hr.
20 min.
F101
2,72 A
Normal operated.
Input current stabilised at 2,72A.
Sub transformer primary winding
heated up to 105K and stabilised.
Dielectric strength test OK.
No hazard.
Input current stabilised at 2,72A.
Sub transformer primary winding
heated up to 105K and stabilised.
Dielectric strength test OK.
No hazard.
C215 -
S-c
253
26 min.
F101
0,09 A
Sub transformer primary winding
heated up to 145K and thermal
fuse opened after 26 min.
Dielectric strength test OK.
No hazard.
heated up to 145K and thermal
fuse opened after 26 min.
Dielectric strength test OK.
No hazard.
D112
A - C
S-c
253
58 sec.
F101
2,93 A
Sub transformer primary winding
heated up to 151K and thermal
fuse opened after 58 sec.
Dielectric strength test OK.
No hazard.
(Repeated test two more times
with similar result)
- T/F opened at 152K after 57 sec.
- T/F opened at 155K after 55 sec.
No hazard.
heated up to 151K and thermal
fuse opened after 58 sec.
Dielectric strength test OK.
No hazard.
(Repeated test two more times
with similar result)
- T/F opened at 152K after 57 sec.
- T/F opened at 155K after 55 sec.
No hazard.
C116 -
S-c 253
1
min.
4 sec.
F101 3,00
A
Sub transformer primary winding
heated up to 152K and thermal
fuse opened after 1 min. 4 sec.
Dielectric strength test OK.
No hazard.
(Repeated test two more times
with similar result)
- T/F opened at 151K after 58 sec.
- T/F opened at 153K after 57 sec.
No hazard.
heated up to 152K and thermal
fuse opened after 1 min. 4 sec.
Dielectric strength test OK.
No hazard.
(Repeated test two more times
with similar result)
- T/F opened at 151K after 58 sec.
- T/F opened at 153K after 57 sec.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
TRF No: IEC/EN 60065F