Read Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate online
- Page 4 of 8 -
Order
No.
72390
11
FAULT CONDITON TESTS -continued
P
Comp.
No.
No.
Location
Fault Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
Q518
E - C
S-c
253
10 min.
F101
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
Q519 damaged.
No hazard.
Input current stabilised at 0,06A.
Q519 damaged.
No hazard.
Q518
B - C
S-c
253
10 min.
F101
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
C501
-
S-c
253
30 min.
F101
2,51 A
Normal operated.
Input current stabilised at 2,51A.
R525 opened.
No hazard.
Input current stabilised at 2,51A.
R525 opened.
No hazard.
Q519
E - C
S-c
253
10 min.
F101
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
Q518 damaged.
No hazard.
Input current stabilised at 0,06A.
Q518 damaged.
No hazard.
Q519
B - C
S-c
253
10 min.
F101
0,06 A
Unit shut down immediately.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
Input current stabilised at 0,06A.
No component damaged.
No hazard.
D601
AC - “+”
S-c 253
30
min. F101,
F601,
F602
F602
2,72 A
Normal operated.
Input current stabilised at 2,72A.
F602 opened.
No hazard.
Input current stabilised at 2,72A.
F602 opened.
No hazard.
D601
AC - “+”
S-c 207
30
min. F101,
F601,
F602
F602
2,55 A
Normal operated.
Input current stabilised at 2,55A.
F602 opened.
No hazard.
Input current stabilised at 2,55A.
F602 opened.
No hazard.
C606 -
S-c 253
30
min. F101,
F601,
F602
F602
2,69 A
Normal operated.
Input current stabilised at 2,69A.
F601, F602 opened.
No hazard.
Input current stabilised at 2,69A.
F601, F602 opened.
No hazard.
D201
AC - “+”
S-c 253
1
sec. F101 -
F101 opened immediately.
Input current stabilised at 0,06A.
No hazard.
Input current stabilised at 0,06A.
No hazard.
D201
AC - “+”
S-c 207
1
sec. F101 -
F101 opened immediately.
Input current stabilised at 0,03A.
No hazard.
Input current stabilised at 0,03A.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
TRF No: IEC/EN 60065F
Click on the first or last page to see other AVR 445 (serv.man2) service manuals if exist.