AVR 445 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 37

Read Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate online

 
 
- Page 4 of 8 - 
 
 
   
 Order 
No. 
72390
 
 
 
11 
FAULT CONDITON TESTS -continued 
Comp. 
No. 
Location 
Fault   Test V 
Test 
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
Q518 
E - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
Q519 damaged. 
No hazard. 
Q518 
B - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
C501 
S-c 
253 
30 min. 
F101 
2,51 A 
Normal operated. 
Input current stabilised at 2,51A. 
R525 opened. 
No hazard. 
Q519 
E - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
Q518 damaged. 
No hazard. 
Q519 
B - C 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
D601 
AC - “+” 
S-c 253 
30 
min. F101, 
F601, 
F602 
2,72 A 
Normal operated. 
Input current stabilised at 2,72A. 
F602 opened. 
No hazard. 
D601 
AC - “+” 
S-c 207 
30 
min. F101, 
F601, 
F602 
2,55 A 
Normal operated. 
Input current stabilised at 2,55A. 
F602 opened. 
No hazard. 
C606 - 
S-c 253 
30 
min. F101, 
F601, 
F602 
2,69 A 
Normal operated. 
Input current stabilised at 2,69A. 
F601, F602 opened. 
No hazard. 
D201 
AC - “+” 
S-c 253 
sec.  F101  - 
F101 opened immediately. 
Input current stabilised at 0,06A. 
No hazard. 
D201 
AC - “+” 
S-c 207 
sec.  F101  - 
F101 opened immediately. 
Input current stabilised at 0,03A. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded 
TRF No:  IEC/EN 60065F 
Page of 46
Display

Click on the first or last page to see other AVR 445 (serv.man2) service manuals if exist.