FAULT CONDITIONS TESTS 
 
Voltage(V) 0,9 or 1,1 times rated voltage………. 
207V or 253V 
— 
 
Ambient temperature(℃)…………………………… 
23 - 26°C 
— 
Comp. 
No. 
Location 
Fault   Test V 
Test 
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
D801 
AC - “+” 
S-c 
253 
1 sec. 
F101 
F101 opened immediately. 
Input current stabilised at 0,06A. 
No hazard. 
D801 
AC - “+” 
S-c 
207 
1 sec. 
F101 
F101 opened immediately. 
Input current stabilised at 0,03A. 
No hazard. 
C572 
S-c 
253 
10 min. 
F101 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
C572 
S-c 
253 
10 min. 
F101 
0,03 A 
Unit shut down immediately. 
Input current stabilised at 0,03A. 
No component damaged. 
No hazard. 
D502 
AC - “+” 
S-c 
253 
10 min. 
F101, 
F501, 
F502 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
D502 
AC - “-” 
S-c 
253 
30 min. 
F101, 
F501, 
F502 
3,42 A 
Normal operated. 
Input current stabilised at 2,76A. 
F502 opened. 
No hazard. 
C509 
S-c 253 
10 
min. F101, 
F501, 
F502 
0,06 A 
Unit shut down immediately. 
Input current stabilised at 0,06A. 
No component damaged. 
No hazard. 
D505 
AC - “+” 
S-c 253 
15 
min. F101, 
F505, 
F506 
2,73 A 
DC Fan motor stop immediately. 
Unit shut down after 9min. 32sec.
Input current stabilised at 0,06A. 
F505 opened. 
No hazard. 
D505 
AC - “+” 
S-c 253 
15 
min. F101, 
F505, 
F506 
2,55 A 
DC Fan motor stop immediately. 
Unit shut down after 8min. 15sec.
Input current stabilised at 0,03A. 
F505 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded 
TRF No:  IEC/EN 60065F 
Page of 46