72390
14.3.3
Transformer/motor, constructional requirements
P
Clearances / Creepage distances
Transformer
Part No.
Part No.
Insulation
between
between
Insulation Res.
M Ohms
Test Volt
kV (60 sec.)
Measured
Required
H03-TXPWMEI92B0R
Pri. - Sec.
> 100
3000Vac
9,0 / 9,0mm
4,0 / 5,8mm
Pri. - ic
> 100
3000Vac
8,5 / 8,5mm
4,0 / 5,0mm
H03-TXPWMEI45B0R
Pri. - Sec.
> 100
3000Vac
6,8 / 6,8mm
4,0 / 5,4mm
Pri. - ic
> 100
3000Vac
6,1 / 6,5mm
4,0 / 5,0mm
-
Components / construction
(H03-TXPWMEI92B0R)
Windings on two separate bobbins. The bobbins are placed in
an insulating housing with two compartments, one above the
other. Bobbin thickness: > 0,4mm.
Measured Maximum working voltage: 387Vpeak / 274Vrms
an insulating housing with two compartments, one above the
other. Bobbin thickness: > 0,4mm.
Measured Maximum working voltage: 387Vpeak / 274Vrms
P
-
Components / construction
(H03-TXPWMEI45B0R)
Windings on single bobbins. Center wall (2 layers) is provided
between primary and secondary windings. Satisfactory
constructed. Bobbin thickness: > 0,4mm.
Measured Maximum working voltage: 374Vpeak / 264Vrms
between primary and secondary windings. Satisfactory
constructed. Bobbin thickness: > 0,4mm.
Measured Maximum working voltage: 374Vpeak / 264Vrms
P
Transformer
Part No
Part No
Insulation
Between
Between
Thick (mm)
X Number
Material
Dielectric strength test
60 sec.
H03-TXPWMEI92B0R
Pr - sec
0,80 mm min. x 1
PBT bobbin
1 layer tested - Pass *)
Pr - ic
0,80 mm min. x 1
PBT bobbin
1 layer tested - Pass *)
H03-TXPWMEI45B0R
Pr - sec
0,40 mm min. x 2
0,40 mm min. x 1
0,40 mm min. x 1
PET bobbin wall
PBT bobbin cap.
PBT bobbin cap.
1 layer tested - Pass *)
Pr - ic
0,60 mm min. x 1
PET bobbin
1 layer tested - Pass *)
Pr - ic
0,40 mm min. x 1
PBT bobbin cap.
1 layer tested - Pass *)
*) Test voltage: 3000 Vrms.
17.1
Torque test to Table 20:
P
Material
Screw
Location / function
Location / function
Diameter
(mm)
(mm)
With
Head
Without
Head
Screw
Nut
Torque test (Nm)
Fulfilled / Remarks
Fixing of top cover
(Sides)
(Sides)
4
x
Metal
Metal
Tested with 1,2Nm,
5 times / Pass
5 times / Pass
Fixing of top cover
(Rear)
(Rear)
3
x
Metal
Metal
Tested with 0,5Nm,
5 times / Pass
5 times / Pass
TRF No: IEC/EN 60065F