Read Harman Kardon AVR 335 EMC - CB Certificate online
Reference No. : 54120503C Page 18
◀ Anam EMC Test Laboratory ▶
10. VOLTAGE FLUCTUATIONS-FLICKER
10.1. Operating environment
Temperature
: 18℃
Relative humidity : 40%
10.2. Test set-up and procedure
The open circuit test voltage was the rated voltage of the EUT.
The reference impedance was a conventional impedance being used to calculate
or measure the disturbance caused by an appliance.
or measure the disturbance caused by an appliance.
The measurement was performed with the Test software (Version 3.07.04)
for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
10.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
Signal Generator
Anritsu
MG3632A
MT79870
Reference impedance
Voltech
IEC Standard 555
IB16/0725
Universal power analyzer Voltech
PM 3300
AK19/1137
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
10.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex D (2 Copies).