Read Harman Kardon AVR 335 EMC - CB Certificate online
Reference No. : 54120503C Page 12
◀ Anam EMC Test Laboratory ▶
7.5. Test protocols
Date: December 28, 2004
Antenna terminal disturbance voltage due to the local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
1
98.2
54.0
38.1
2
196.4
50.0
*
3
294.6
50.0
*
4
392.8
52.0
*
87.5 5 491.0
52.0 *
6
589.2
52.0
*
7
687.4
52.0
33.5
8
785.6
52.0
31.2
9
883.8
52.0
*
10
982.0
52.0 *
1
100.8
54.0
39.9
2
201.6
50.0
30.2
3
302.4
52.0
*
4
403.2
52.0
*
90.1 5 504.0
52.0 *
6
604.8
52.0
*
7
705.6
52.0
32.6
8
806.4
52.0
31.1
9
907.2
52.0
*
1
108.7
54.0
42.3
2
217.4
50.0
32.8
3
326.1
52.0
31.2
98.0 4 434.8
52.0 *
5
543.5
52.0
30.3
6
652.2
52.0
*
7
760.9
52.0
37.7
8
869.6
52.0
30.9
9
978.3
52.0
*
Click on the first or last page to see other AVR 335 service manuals if exist.