Read Harman Kardon AVR 335 EMC - CB Certificate online
Reference No. : 54120503C Page 14
◀ Anam EMC Test Laboratory ▶
8. DISTURBANCE POWER
8.1. Operating environment
Temperature
: 12℃
Relative humidity : 40%
8.2. Test set-up and procedure
The EUT was placed on a non-metallic table of 0.8m height. At the side of the
EUT a non-metallic table of 6m length was placed to provide for movement of
the absorbing clamp. The absorbing clamp was applied successively to all leads
whose length was 25 ㎝ or longer, unscreened or screened. For the read, the
maximum measured value at each frequency which was obtained when the
absorbing clamp is moved along the lead was registered. No metallic object,
including a possible other unit of the EUT or any person, was closer to the lead
or unit than 0.8m. All screened and unscreened cables were measured with an
absorbing clamp, according to EN 55013, 5.6.
absorbing clamp, according to EN 55013, 5.6.
8.3. Measurement uncertainty
Radio interference power: ±2.0 ㏈
The Measurement uncertainty describes the overall uncertainty of the given
measured value during operation of the EUT in the above-mentioned way.
measured value during operation of the EUT in the above-mentioned way.
8.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
Spectrum monitor
R & S
EZM
862064/004
R & S
ESVP
861743/024
Measurement
receiver
receiver
R & S
ESCS30
847124/017
Absorbing clamp
R & S
MDS 21
860846/006
Oscillator Kenwood
AG-203A
3090241
* R & S: Rohde & Schwarz
8.5. Test protocols
Date: December 08, 2004
The equipment does comply with the requirements.
Operating condition: The EUT continuously operated with audio frequency
of 1,000 ㎐ being supplied from the Oscillator.
An absorbing clamp was placed around all leads.
At each mode, the maximum value at each testing frequency and each output
lead was registered and attached as follows.
of 1,000 ㎐ being supplied from the Oscillator.
An absorbing clamp was placed around all leads.
At each mode, the maximum value at each testing frequency and each output
lead was registered and attached as follows.
Click on the first or last page to see other AVR 335 service manuals if exist.