AVR 335 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 19

Read Harman Kardon AVR 335 EMC - CB Certificate online

Reference No. : 54120503C                                                                                                                        Page 17
 
◀  Anam EMC Test Laboratory  ▶
 
 
9. HARMONICS 
  9.1. Operating environment 
Temperature 
: 18℃ 
Relative humidity  : 40% 
 
    9.2. Test set-up and procedure 
 
Harmonics of the fundamental current were measured up to 2 ㎑ using a 
 
universal power analyzer. The measurement was carried out under steady   
 
conditions and using averaging. 
 
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2 : 2000. 
 
The measurement was performed with the Test software (Version 3.07.04)   
for Windows 
The input signal and load conditions were set as given in clause 4.2.4 of   
IEC 60065. 
 
   9.3. Test instrumentation 
Equipment 
Mfr. 
Type No. 
Serial No. 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
Universal power analyzer  Voltech 
PM 3300 
AK19/1137 
Programmable controller 
Pacific 
360AMXT/UPC32 
151 
Magnetics module 
Pacific 
134310 
334 
 
9.4. Test result 
 
The equipment does comply with the requirements. 
For the measurement data, see Annex C (3 Copies). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 