Read Harman Kardon AVR 335 EMC - CB Certificate online
Reference No. : 54120503C Page 13
◀ Anam EMC Test Laboratory ▶
Antenna terminal disturbance voltage due to the local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
1
110.8
54.0
42.7
2
221.6
50.0
30.9
3
332.4
50.0
*
4
443.2
52.0
*
100.1 5 554.0
52.0 *
6
664.8
52.0
*
7
775.6
52.0
38.5
8
886.4
52.0
*
9
997.2
52.0
*
1
116.8
54.0
43.7
2
233.6
50.0
32.4
3
350.4
52.0
30.9
4
467.2
52.0
*
106.1 5 584.0
52.0 *
6
700.8
52.0
*
7
817.6
52.0
38.9
8
934.4
52.0
*
1
118.7
54.0
42.1
2
237.4
50.0
31.3
3
356.1
52.0
30.1
108.0 4 474.8
52.0 *
5
593.5
52.0
*
6
712.2
52.0
*
7
830.9
52.0
38.3
8
949.6
52.0
*
OTHERS
Antenna terminal disturbance voltage due to other source than local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
98.0 / 46.0 *
*: less than 30 ㏈㎶
Limit according to EN55013:2001
Click on the first or last page to see other AVR 335 service manuals if exist.