AX1100(R)M
10 – 1
AX1100(R)M
Service Manual
 
CHAPTER 10. 
ERROR LIST
[1] Error List
How to operate test mode
(Power on and door closed)
STOPSTEAM HIGHMICRODoor openSelect Test No. 2by [WEIGHT UP/ DOWN]STARTSelect Address
04h (or 05h)
START
EE code: EE code is memorized in the FLASH address 04h as error history.  (Only antenna error code is memorized in the FLASH address 05h.) 
NOTE: When an error mode occurs except for shortage of water error and the oven stopping state continues for more than 3 minutes, the oven will
be powered off by Energy save mode function.
Error 
display
EE 
code
Detail of error
Error condition
Application 
menu
Check method
Check timing
Note
Err
04
Oven temperature 
is high.
Oven temperature is too 
high 
Defrost
Steam Low
(under 85
C)
Grill thermistor
Immediately
“HOT” is blinking 
in the display.
Err
0F
Water tank is frozen
Engine heater tempera-
ture is too low.
Engine menu
Grill thermistor
Always
Err
-
Time input error
More than maximum 
cooking time is input
Manual steam 
menu
Key input
Steam High/Low 
key is pressed.
Err
0A
Shortage of Water
Water in the water tank 
isn't enough. 
Tube pump assembly or 
pump motor is out of 
order.
Engine menu 
except Defrost 
menu
Engine thermistor
Grill thermistor
After engine heater 
was from on to off 
once.
The cooking is 
stopped.
Only stop/clear 
key is available.
Error 
display
EE 
code
Detail of error
Error condition
Application menu
Check timing
Note
EE01
11
Grill thermistor 
error SHORT
Grill thermistor is short.
Oven mode
Immediately from 
heating start
12
Grill thermistor 
error OPEN
Grill thermistor is open.
Fermentation mode
Always from heating 
start
EE05
15
Engine heater error
Engine heater temperature is 
too high.
Engine menu
Always from heating 
start
18
Intake Damper 
error
Damper or Damper switch doesn't work.
Damper is stopped if on and off at damper switch port is 
not detected within 1 min.
When Damper error is detected, the cooking is stopped.
Every mode that 
damper works.
Error isn't displayed.
EE code is memorized 
in the FLASH address 
04h, if other error has 
not occurred.
01
Antenna error
Antenna or antenna switch doesn't work.
When antenna error is detected, output of microwave is 
stopped.
Microwave mode
Error isn't displayed.
EE code is memorized 
in the FLASH address 
05h.
EE12
1C
Engine thermistor 
error OPEN
Engine thermistor is open.
Engine menu
Always operate 
more than 30sec. 
under 5 bit.
EE14
1E
FLASH error 
(FLASH data verifi-
cation error)
FLASH Read data is not 
same as FLASH write data.
PWB short check pro-
gram
Short check pro-
gram
RESET
-
Something is burn-
ing in the oven by 
MICRO heating.
Rapid changes in oven ther-
mistor level.
All cooking mode or 
stop state, check oven 
thermistor level continu-
ously.
After 5min.
When the error 
detected, power is cut 
off.
AX1100(R)M
10 – 2
[2] How to check in the event of an error
1. How to check water supply performance
Check the plumbing of the tubes.
If the plumbing is normal, check the performance of the tube pump assembly.
1) Check of plumbing
2) Check of tube pump performance
NO
NO
Are tubes bended?
Are tubes broken?
Are tubes choked?
Are tubes inserted certainly?
Yes
Yes
Repair or exchange the tube.
Is the plumbing of tubes correct?
Correct the plumbing.
Check the performance of the tube pump assembly.
NO
NO
NO
NO
YES
YES
YES
NO
YES
YES
Mesure the weight of the water tank filled with
water to MAX mark.(This is initial weight A g.)
Set the water tank to the oven and power ON
( open the door and close.).
Engine unt
Start the 10 minutes Steam High cooking.
Feed-water
inlet
Confirm that water is flowing at the feed-water
inlet of the engine unit.
The 10-minutes
5VGCO*KIJEQQMKPI is finished.(For the last
one (1) minute, the pump motor does not run to evaporate
dew in engine unit.)
Open the door and drop water remaining in the oven cavity into the drip tray. Then close the door.
Cast off accumlated water in the drip tray.
Ensure that the drip tray is empy and set it to the oven.
Remove the water tank from the oven.
Afte 20 seconds, remove the drip tray and return accumlated
water in the drip tray to the water tank.
Normal
Measure the weight of water tank.
(Weight after operation is B g .)
Is the weight reduction ( = A-B ) equal tor more
than 100 g ?
Are the wire leads connected to the pump
motor and thecontrol unit ?
Is there rating voltage at the motor
terminal ?
Is there breakage or clogging the tubes ?
After stopping the operation,
connect the wire leads.
Replace the control unit.
Press the Stop key to stop
operating.
Press the Stop key to stop operating.
Replace or repair the tubes.
Replace the pump motor or the tube pump assembly.
AX1100(R)M
10 – 3
2. How to check performance of thermistor (Engine) 
3. How to check thermistor (Grill) performance
4. EE01 thermistor (Grill) failure
✩ Before starting the P.W.B. unit replacement, make sure to refer to “Before replacing the Printed Wiring Board” in page 2-1.
YES
NO
Set the water tank, which has been filled with water to the MAX mark, to the set and power ON.
(Confirm that there is no water remaining in the oven cavity.)
Set the test mode to 10. (See How to operate test mode on page 11-1)
Press the START key.
The pump motor will operate for 30 seconds.
And then Microwave heating (for 1 minute) starts automatically.
Steam High operation (for 30 minutes) starts automatically.
After 2minutes, "CHECK" appears in the display automatically.
Is thermistor (Engine) failure (00 00 or 00 00 ) indicated?
EE12: Proceed to checking the thermistor (Engine) for failure.
Remove the water tank and press the START key.
The test mode 6 will be carried out and remained water in the engine
unit assembly will be evaporated
Normal termination (Indication: 11 11)
YES
NO
YES
NO
EE01: Proceed to checking the thermistor (grill) for failure.
Press the START key.
Does a measured value for the thermistor (grill) change as oven heating proceeds?
Is the measured value within ±10 bits with respect to the
standard value after about eight (8) minutes?
Set the test mode to 03.
(See How to operate test mode on page 11-1)
Power ON the main body.(Open and close the door.)
Press the STOP key to finish the operation. (This action is required when everything is OK.)
NO
YES
YES
NO
Measure the thermistor (grill) resistance using a tester with the thermistor
connecting connector pulled out of the wire harness.
The thermistor (grill) resistance is within its appropriate range.
Is the connector between the thermistor (grill) and wire harness either
disconnected or shorted?
Connect or repair the connector.
Replace the thermistor (grill).
Replace the control unit.
AX1100(R)M
10 – 4
5. EE12 Engine thermistor failure
✩ Before starting the P.W.B. unit replacement, make sure to refer to “Before replacing the Printed Wiring Board” in page 2-1.
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
Measure the thermistor (Engine) resistance using a tester with the thermistor
connector pulled out of the control unit.
Are there disconnection, breakage and short circuit in the engine heater
connections (the engine terminals and control unit)?
Is the engine heater normal to meet the following requirements?
Insulation resistance: One (1) M or more at 500 VDC
Dielectric strength: 1000 V for one (1) minute
Leakage current: 0.3 mA or less
Resistance (in cold condition): 58.0 to 62.9
The monitored interlock switch is
in the door open position.
Is the engine thermal cut-out
normal?
Adjust the latch.
Replace the engine
thermal cut-outt
Is the connectors between the thermistor (Engine), and wire harness disconnected or short circuited?
Connect/repair the terminal(s) or replace the harness.
Replace the thermistor (Engine).
Replace the engine unit.
Replace the control unit.
The thermistor (engine) resistance is within its appropriate range.
About 200 k
at
About 10 k
at
About 1 k at
Is there rating voltage between the engine heater terminals?
Connect/repair the connector(s) or replace
the thermistor/harness.
Page of 4
Display

Download Sharp AX-1100(R)M / AX-1100(SL)M (serv.man9) Service Manual (Repair Manual)

Here you can read online and download Sharp AX-1100(R)M / AX-1100(SL)M (serv.man9) Service Manual in PDF. AX-1100(R)M / AX-1100(SL)M (serv.man9) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AX-1100(R)M / AX-1100(SL)M (serv.man9) Microwave Oven. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.