Read Harman Kardon AVR 132 (serv.man2) EMC - CB Certificate online
- Page 4 of 7 -
www.nemko.com
Report No. 70635
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Location Fault
Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
D992
AC - +
S-c
253
10 min
F901
6,20 A
Unit shut down immediately.
Input current stabilised at 0,014A.
No component damaged.
No hazard.
Input current stabilised at 0,014A.
No component damaged.
No hazard.
D962
A - C
S-c
253
9 min
-
1,14 A
Sub transformer primary winding
heated-up to 99K and thermal fuse
opened after 9 min.
Dielectric strength test O.K.
No hazard.
heated-up to 99K and thermal fuse
opened after 9 min.
Dielectric strength test O.K.
No hazard.
D901
A - C
S-c
253
8 min
-
1,15 A
Sub transformer primary winding
heated-up to 98K and thermal fuse
opened after 8 min.
Dielectric strength test O.K.
No hazard.
heated-up to 98K and thermal fuse
opened after 8 min.
Dielectric strength test O.K.
No hazard.
C906
A - C
S-c
253
10 min
-
0,038 A Unit shut down immediately.
Sub transformer primary winding
heated-up to 102K and thermal
fuse
opened after 10 min.
Dielectric strength test O.K.
No hazard.
heated-up to 102K and thermal
fuse
opened after 10 min.
Dielectric strength test O.K.
No hazard.
C902
-
S-c
207
10 min
F901
3,10 A
Unit shut down immediately.
Input current stabilised at 0,008A.
No component damaged.
No hazard.
Input current stabilised at 0,008A.
No component damaged.
No hazard.
C902
-
S-c
253
10 min
F901
3,60 A
Unit shut down immediately.
Input current stabilised at 0,014A.
No component damaged.
No hazard.
Input current stabilised at 0,014A.
No component damaged.
No hazard.
C915
-
S-c
207
10 min
F901
3,90 A
Unit shut down immediately.
Input current stabilised at 0,008A.
No component damaged.
No hazard.
Input current stabilised at 0,008A.
No component damaged.
No hazard.
C915
-
S-c
253
10 min
F901
4,30 A
Unit shut down immediately.
Input current stabilised at 0,014A.
No component damaged.
No hazard.
Input current stabilised at 0,014A.
No component damaged.
No hazard.
Q657
C - E
S-c
253
10 min
F901
4,10 A
Unit shut down after 3 sec.
Input current stabilised at 0,014A.
Q661 damaged.
No hazard.
Input current stabilised at 0,014A.
Q661 damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection