Read Harman Kardon AVR 132 (serv.man2) EMC - CB Certificate online
- Page 6 of 7 -
www.nemko.com
Report No. 70635
13.3 - 13.4
Clearances and Creepage distances
P
Type of
Insulation
Position/
Location
Location
Position/
Location
Location
Working
Voltage
Clearance
13.3.2
Creepage dist.
13.4
Comm.
1 2
Up
Urms
Req.
Measu.
Req.
Measu.
Basic Live Neutral 326V
230V
2,0mm
3,5mm 2,5mm
3,5mm
1)
Reinforce Primary
Chassis
326V 230V 4,0mm 7,3mm 5,0mm >
7,3mm 2)
Reinforce Primary
Chassis
326V 230V 4,0mm 7,0mm 5,0mm >
7,0mm 3)
Reinforce Primary *)
Chassis
326V
230V
4,0mm
5,9mm 5,0mm > 5,9mm 4)
Reinforce Primary
Chassis
326V 230V 4,0mm 5,2mm 5,0mm 5,2mm 5)
Reinforce Primary
Secondary 379V 268V 4,0mm 6,0mm 5,6mm 6,0mm 6)
*) 2N force applied
Note: U in Volt, Clearances/Creepage Distances in mm, Comm. = Comment
Comments:
1) Measured on PCB before mains fuse
2) Measured between primary pcb trace and near metal chassis (back cover).
3) Measured between main pcb primary solder pin and metal bottom chassis.
4) Measured between main pcb primary trace and embossed metal bottom chassis.
5) Measured on main pcb from pri. pcb trace to metal chassis connected sec. pcb trace.
6) Measured on main pcb from pri. pcb trace to near secondary pcb trace.
2) Measured between primary pcb trace and near metal chassis (back cover).
3) Measured between main pcb primary solder pin and metal bottom chassis.
4) Measured between main pcb primary trace and embossed metal bottom chassis.
5) Measured on main pcb from pri. pcb trace to metal chassis connected sec. pcb trace.
6) Measured on main pcb from pri. pcb trace to near secondary pcb trace.