AVR 132 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 44

Read Harman Kardon AVR 132 (serv.man2) EMC - CB Certificate online

 
 
- Page 2 of 7 - 
 
 
www.nemko.com
 
Report No.  70635 
 
 
11 
FAULT CONDITIONS TESTS
 
 
Voltage (V) 0,9 or 1,1 times rated voltage ............. :
207V or 253V 
— 
 
Ambient temperature (
o
C) ...................................... :
23 -26 °C 
— 
Comp. 
No. 
Location  Fault 
Test V 
Test  
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
D112 
A - C 
S-c 
253 
30 min 
F901 
1,33 A 
Normal operated. 
Input current stabilised at 1,10A. 
R115
 
opened. 
No hazard. 
C124 
S-c 
253 
10 min 
F901 
1,22 A 
Normal operated. 
Input current stabilised at 1,12A. 
R114, R115
 
opened. 
No hazard. 
D114 
A - C 
S-c 
253 
30 min 
F901 
1,22 A 
Normal operated. 
Input current stabilised at 1,13A. 
R104
 
opened. 
No hazard. 
D117 
A - C 
S-c 
253 
30 min 
F901 
1,16 A 
Normal operated. 
Input current stabilised at 1,12A. 
R105
 
opened. 
No hazard. 
D104 
A - C 
S-c 
253 
30 min 
F901 
1,15 A 
Normal operated. 
Input current stabilised at 1,12A. 
R106
 
opened. 
No hazard. 
C914 
S-c 
253 
10 min 
F901 
1,51 A 
Normal operated. 
Input current stabilised at 1,07A. 
R106, R107
 
opened. 
No hazard. 
C930 
S-c 
253 
10 min 
F901 
1,60 A 
Unit shut down after 1 sec. 
Input current stabilised at 0,014A. 
R104, R105
 
opened. 
No hazard. 
D118 
A - C 
S-c 
253 
20 min 
F901 
0,51 A 
Output signal off immediately. 
Input current stabilised at 0,42A. 
R116, R117 opened. 
No hazard. 
C128 
S-c 
253 
30 min 
F901 
1,69 A 
Output signal dropped to 3,3V 
immediately. 
Input current stabilised at 0,68A. 
R116, R117
 
opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection 
         
         
 