AVR 132 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 45

Read Harman Kardon AVR 132 (serv.man2) EMC - CB Certificate online

 
 
- Page 3 of 7 - 
 
 
www.nemko.com
 
Report No.  70635 
 
 
11 
FAULT CONDITIONS TESTS-continued
 
Comp. 
No. 
Location  Fault 
Test V 
Test  
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
D121 
A - C 
S-c 
253 
10 min 
F901 
1,52 A 
Normal operated. 
Input current stabilised at 1,12A. 
R117
 
opened. 
No hazard. 
C129 
S-c 
253 
10 min 
F901 
1,84 A 
Output signal off immediately. 
Input current stabilised at 0,41A. 
R116, R117 opened. 
No hazard. 
D122 
A - C 
S-c 
253 
10 min 
F901 
1,17 A 
Normal operated. 
Input current stabilised at 1,12A. 
R118
 
opened. 
No hazard. 
C130 
S-c 
253 
10 min 
F901 
1,54 A 
Normal operated. 
Input current stabilised at 1,12A. 
R118, R119
 
opened. 
No hazard. 
D108 
A - C 
S-c 
253 
20 min 
F901 
1,31 A 
Normal operated. 
Input current stabilised at 1,12A. 
R101
 
opened. 
No hazard. 
C122 
S-c 
253 
30 min 
F901 
1,36 A 
Normal operated. 
Input current stabilised at 1,11A. 
R101
 
opened. 
No hazard. 
C117 
S-c 
253 
20 min 
F901 
1,13A 
Normal operated. 
Input current stabilised at 1,13A. 
No component damaged. 
No hazard. 
D991 
AC - + 
S-c 
207 
10 min 
F901 
4,80 A 
Unit shut down immediately. 
Input current stabilised at 0,008A. 
No component damaged. 
No hazard. 
D991 
AC - + 
S-c 
253 
10 min 
F901 
7,10 A 
Unit shut down immediately. 
Input current stabilised at 0,014A. 
No component damaged. 
No hazard. 
D992 
AC - + 
S-c 
207 
10 min 
F901 
5,80 A 
Unit shut down immediately. 
Input current stabilised at 0,008A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection 
 