ABH-4 (serv.man10) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 14

Read Harman Kardon ABH-4 (serv.man10) EMC - CB Certificate online

 
page 9 of 42 
Report No.SPCLVD31229 
 
      
 
TRF No.: I950___D 
TRF originator: FIMKO 
 
2.2 
SELV circuits 
Pass 
2.2.1 
General requirements 
SELV levels are maintained 
after single fault condition. 
Pass 
2.2.2 
Voltages under normal conditions (V) ................ :  All accessible voltages are 
less than 42.4 Vp or 60 V dc 
and are classified as SELV. 
Pass 
2.2.3 
Voltages under fault conditions (V) .................... :  Under fault conditions 
voltages never exceed 71V 
peak and 120Vdc and do not 
exceed 42.4V peak or 60V dc 
for more than 0.2 sec. 
Pass 
2.2.3.1 
Separation by double or reinforced insulation 
(method 1) 
Hazardous voltage wiring 
which may contact SELV 
parts provided with double or 
reinforced insulation.  See 
2.10.5. 
Pass 
2.2.3.2 
Separation by earthed screen (method 2) 
Method 1 used. 
N/A 
2.2.3.3 
Protection by earthing of the SELV circuit (method 
3) 
Method 1 used. 
N/A 
2.2.4 
Connection of SELV circuits to other circuits....... :  SELV circuit and all 
interconnected circuits 
separated from primary by 
Reinforced/Double insulation.   
The SELV circuit does not 
exceed the SELV limits under 
normal and fault conditions. 
SELV circuits are only 
connected to other secondary 
circuits. 
Pass 